2. Application technical notes
Soft-body (thrown ball) impact
SECURIT and STADIP have been tested for soft-body (thrown ball) impact to DIN 18032 Part 3 as suitable for sports halls.
Acoustic insulation
Minimum requirements to Austrian Standard ÖNORM B 8115-2:
Interior doors general – Rw > 28 dB
Doors in staircases, Hotels, Hospitals or rooms with higher requirements – Rw ≥ 33 dB
eckelt.DOORS fulfill these requirements depending on the door type – see technical characteristics. Special compositions using STADIP SILENCE can achieve acoustic insulation of up to Rw 37 dB.
To achieve Standard-compliant performance it is necessary to provide suitable casement and threshold seals.
Even an acoustic insulation improvement of 3 dB halves the human perception of noise.
| Noise frequency values |
| 10 – 20 dB |
whispering |
| 30 – 50 dB |
quiet residential street, radio at room loudness |
| 60 – 80 dB |
loud street, vacuum-cleaner, barking |
| 90 – 95 dB |
circular saw, screeching brakes |
| 120 dB |
pain threshold |
Climate effects
eckelt.DOORS are in contrast to wood doors not sensitive to warping as a result of temperature or humidity.
Tolerances
Dimensional and edge tolerance ± 1 mm
Other tolerances [>]
General cleaning recommendations [>]