SGG SECURIT Technology

Thermally toughened safety glass to EN 12150-1

1. Dimensions

 
up to 2800 x 6000 mm
Minimum 100 x 300 mm
Aspect ratio 1:20
Cast glass max. dimensions
4 mm 900 x 1800 mm
5 mm 1000 x 2000 mm
6 mm 1500 x 2500 mm
8 mm 2000 x 3000 mm
10 mm 2000 x 3600 mm
 
 

2. Application technical Notes

  • The thermal tempering requires that subsequent treatments to the glass such as cutting, grinding, drilling etc. are not carried out. This can result in breakage or at least in a reduction of the material characteristics of the glass!
    All finishes to the glass must therefore be carried out prior to tempering.

  • Anisotrophy
    Irrisation occurrences in thermally treated glass. In viewing the Fully Tempered safety glass under certain light conditions and polarised it is possible that a pattern in the glass becomes visible. This is Anisotrophy or so called polarisation fields. This is a physical phenomenon and a normal characteristic of FT glass.

  • Moisture uniformity on the glass surface
    The surface moisture uniformity on the outside of the glass may vary e.g. due to imprints from rollers, fingers, labels, paper residue, suction pads, sealant residue, smoothing agents, separation agents or environmental influences. Moisture on the glass surface as a result of condensation, rain or cleaning water may have differing levels of uniformity. Such appearances are inherent characteristics and cannot be considered as defects.

  • [PDF] Tolerances
     
  • [PDF] General Glazing Guidelines

  • [PDF] Cleaning and maintenance recommendations
 
 

3. Finishing

3.1 Edge working

Rectangular sheet of SECURIT is manufactured with an arrissed edge as standard.

3.2 Drilled holes

Up to 12 mm Glass thickness
The hole diameter (D) must not be less than
the glass thickness (S).

Glass thickness 15 and 19 mm
Hole diameter at least 18 resp. 25 mm.

Production restrictions on hole locations apply.

 
Arrissed edge (KGS)
 
 

4. Marking

In accordance with EN 12150 all FT Glass is marked

MARKING REQUIREMENTS OUTSIDE OF STANDARDS MUST BE ADVISED PRIOR TO ORDERING.

 
 

5. Certification

Harmonisation certification
FT fulfils the requirements of the German Building regulations A Part 1 2004/1 Nr. 11.4.1.

ECKELT has all requirements and certification for this product in accordance with 89/106/EEC from the Council of the European Union. The applicable CE harmonization certificate can be downloaded on the right of the screen.

ECKELT has carried out impact testing to the requirements of the SGCC and has certification to ANSI Z.97.1-1984 and 16 CFR 1201 (download right).

 
 

6. Technical Data

SECURIT-FT of Float glass is subject to continuous in-house and independent monitoring.