Systemised Wall cladding
Structures or walls normally have differing amounts of expansion compared to the glass in front of them. Point-fixings must therefore be able to freely, and without stress transfer, accommodate temperature and load conditions.
With its patented LITE-POINT solution, this system ensures a functional connection method whilst accommodating the principle of fixed and loose point fixing.
1. System description
1.1 Construction
LITE-POINT System components comprise support brackets, vertical angled profiles and horizontal rail profiles as well as support points for fixed and loose fixings and include all necessary accessories such as washers and screws.
The depth of the construction is determined by the thickness of the insulation and necessary ventilation pocket. Dimensions can be seen in the system section.
Exterior and interior corners as well as recesses have suitable system connectors available.
The anchors for connection of brackets to the wall are not part of the LITE-POINT system.
To determine the ideal thermal insulation material visit the ISOVER website [>]. A general recommendation can be downloaded here on the right side of the page.
1.2 Glass
Technical regulations require LITE-POINT to use of Fully Tempered, HST glass in thicknesses of 8 or 10 mm, which has a minimum of 4 and a maximum of 12 system connection holes.
The following glass types are available for a correct application of the technical guidelines:
[>] EMALIT-H
[>] EMALIT-H BIOCLEAN
[>] SERALIT LITEX-H
[>] SERALIT LITEX-H BIOCLEAN
[>] SECURIT-H from MASTER- or DECORGLASS
|