Keeps you safely out of the rain
ROOFLITE Standard composition is of STADIP laminated safety glass from 2 x heat-strengthened float glass in accordance with EN 1863.
1. System description
Structural dimensioning
A system analysis has been determined for the standard sizes, which complies with Austrian building regulations and are likely to comply with most national regulations where similar conditions apply. The following loads are used as basis for design:
ROOFLITE with clear glass: max. allowable load is 1,4 kN/m²
ROOFLITE with SERALIT LITEX: max. allowable load is 1,0 kN/m²
Site requirements
Where installation is into reinforced concrete or through hollow block walls: maximum snow and surface loads 2,5 kN
Where installation is onto hollow block walls using Fischer FIP anchor: maximum snow and surface loads 1,25 kN
Individual sizes which exceed the maximum standard sizes must be structurally checked.
For Austria:
TÜV-Test dated 27.1.1998
Report number AT 1-S-98/1
|